Customization: | Available |
---|---|
Phase: | Three Phase |
Type: | Line Interactive |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Introduction:
It adopts online double conversion technology, which can completely eliminate all kinds of grid problems and provide customers with stable and pure sinusoidal power supply protection. Innovative design makes these products have unparalleled reliability and high performance. The high input power factor and low input current harmonics ensure the UPS green and environmental protection, and high efficiency ensures the energy saving.
Scenarios:
Small and medium-sized data centers, IT machine rooms, financial institutions, traffic dispatch centers, security monitoring, etc.
Features:
1.Wide input voltage range
2.Online double conversion technology
3.DSP digital control technology
4.Output power factor 0.9
5.N+X redundancy
6.Communications: RS485/Relay card/USB/SNMP option
Benefits:
1.Wide input voltage range adapt to harsh power grid
2.DSP technology greatly improve the system reliability
3.Friendly man-machine interface, easy to operate
4.Intelligent battery management extend battery life
Capacity (VA) | 20 | 30 | 40 | 60 | 80 | 100 | 120 | 150 | 180 | |
Input | Phase | 3 Phase 4 Wires and Ground | ||||||||
Rated Voltage | 380/400/415Vac | |||||||||
Operating voltage range | 208~478Vac | 138~485Vac | ||||||||
Operating frequency range | 40Hz-70Hz | |||||||||
Power factor | ≥0.99 | |||||||||
Harmonic distortion (THDi) | ≤3% (100% non-linear load ) | |||||||||
Bypass voltage range |
Max.voltage: 220Vac +25%(optional +10%,+15%,+20% ); 230Vac: +20%(optional +10%,+15% ); 240Vac: +15%(optional +10% ) |
|||||||||
Min. voltage:-45 %( optional -10%, -20%,-30%) | ||||||||||
Frequency protection range: ±10% | ||||||||||
Generator input | Support | |||||||||
Output | Phase | 3 Phase 4 Wires and Ground | ||||||||
Output voltage | 380/400/415Vac | |||||||||
Power factor | 0.9 | |||||||||
Voltage regulation | ±1% | |||||||||
Output frequency | Utility Mode: ±1%/±2%/±4%/±5%±10% optional; Battery Mode:(50/60±0.1%)Hz | |||||||||
Crest factor | 3:1 | |||||||||
THD | ≤2% with linear load; ≤4% with non linear load | |||||||||
Efficiency | 94.5% | 95.5% | ||||||||
Overload | Load≤110%, last 60min; ≤125%, last 10min; ≤150%, last 1min; >150% change to bypass | |||||||||
Battery | Voltage | ±192V/±204V/±216V/±228V/±240Vdc(32/34/36/38/40pcs optional) |
±180V/192V/±204V/±216V/±228V/±240/±252/±264/±276/±288/±300Vdc (30/32/34/36/38/40/42/44/46/48/50pcs optional) |
|||||||
Charge Current | Max. 10A | Max. 20A | Max. 60A | |||||||
Transfer Time | Utility to Battery : 0ms; Utility to bypass: 0ms | |||||||||
Environment | Operating temperature | 0ºC~40ºC | ||||||||
Storage temperature | -25ºC~55ºC(no battery) | |||||||||
Humidity range | 0~95% (non condensing) | |||||||||
Altitude | < 1500m | |||||||||
Noise level | <55dB | <58dB | <60dB | <65dB | ||||||
Protection | Alarm | overload, utility abnormal, UPS fault, battery low, etc | ||||||||
Protection | short circuit, overload, over temperature, battery low, fan fault alarm | |||||||||
Communication | USB, CAN, RS485, FE, LBS, Parallel card, Relay card, SNMP card(optional) | |||||||||
Physical | Dimension D×W×H (mm) | 690x250x530 | 830x300x700 | 830x300x960 | 850x440x1200 | |||||
Net weight (kg) | 45.5 | 45.8 | 65 | 82.5 | 101 | 140 | 149 | 190 | 199 | |
Standards | EN62040-1, EN62040-2 |