Customization: | Available |
---|---|
Phase: | Single Phase |
Type: | On-line |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
solar power ups Online UPS SOROTEC for solar home ups HP9335C II 10-120KVA with ups and power
Key Features
Double IGBT technical,input PFC>0.99,Thdi<3%;
Efficiency up to 96.5% with three-level technology;
Big charger power reach up to 15% of total power;
Intelligent LCD screen support 12 languages,such as English,Russian.Spanish,French,Korean,Italy,Turkish ;
The internal air channel is designed in such a way that internal hot air drives directly towards the heat sink,
without distressing the PCBs and other internal sensitive circuits.
PRODUCT DESCRIPTIONS |
HP9335C II 10-120K 3ph Input/3ph Output 380/400/415VAC
Model | Standard unit | HP9335C 10-40KT | - | |||||||
Long run unit | HP9335C 10-120K XL | |||||||||
Nominal Ratings(kVA) | 10 | 20 | 30 | 40 | 50 | 60 | 80 | 100 | 120 | |
Input | ||||||||||
Nominal input voltage(V) | 380/400/415 | |||||||||
Input voltage range(V) | 228-478 | |||||||||
Nominal input frequency(Hz) | 50/60 | |||||||||
Input frequency range(Hz) | 40-70 | |||||||||
Bypass voltage tolerance(%) |
Upper limit: +10%, +15%, or +20% default:+15%; Lower limit: -10%, -20%, -30% or -40% default: -20% |
|||||||||
Bypass frequency tolerance(%) | +/- 10% or +/- 20%, default: +/-10% | |||||||||
Input power factor | >0.99 | |||||||||
Current THD at full linear load(THDi%) | <3% | |||||||||
Battery | ||||||||||
Battery voltage | Standard unit | 30pcs 12V 7AH | 30pcs 12V 7AH | 60pcs 12V 7AH | 64pcs 12V 9AH | - | ||||
Long run unit | ±192V~±264Vdc; battery quantity 32-44 pcs (optional) | |||||||||
Temperature compensation (mV/ºC/Cell) | -3.0 (selectable from 0 to -5.0 around 25°C or 30°C, or inhibit) | |||||||||
Battery charger current(A) | 0~20( adjustable) | 0~40( adjustable) | ||||||||
Output | ||||||||||
Nominal output voltage(V) | 380/400/415 | |||||||||
Nominal output frequency(Hz) | 50/60 | |||||||||
Output power factor | 1 | 1 | 1 | 1 | 1 | 0.9 | 1 | 1 | 0.9 | |
THDv with 100% linear load(%) | <1% | |||||||||
Inverter overload capacity | 110% for 60 min; 125% 10min; 150% for 1 min | |||||||||
Efficiency | ||||||||||
Online mode efficiency | Up to 96.5% | |||||||||
ECO-Mode efficiency | Up to 99.1% | |||||||||
Parallel | Parallel up to 6 units | |||||||||
Dimensions and weight | ||||||||||
Dimensions(W×D×H)mm | Standard unit | 300×700×1105 | 300×810×1260 | - | ||||||
Long run unit | 300×700×800 | 360×800×980 | ||||||||
Weight(kg) | Standard unit | 146 | 146 | 194 | 198 | - | ||||
Long run unit | 74 | 74 | 74 | 75 | 75 | 75 | 115 | 116 | 118 | |
General | ||||||||||
Noise at 1m dB(A) | <55dB (1 meter away) | <60dB (1 meter away) | ||||||||
Altitude | ≤1500; derate power by 1% per 100m between 1500m and 300m | |||||||||
Ventilation | Front to back standard | |||||||||
Protection level | IP20 | |||||||||
General and safety | EN62040-1/IEC62040-1 | |||||||||
EMC standars | EN62040-2 / IEC62040-2 | |||||||||
Method of specifying the performance and test | EN62040-3 / IEC62040-3 |
HP9335C II SA 10-60KT 3ph Input/3ph Output 200/208/220VAC
Model | Standard unit | HP9335C SA 10-30KT | - | ||||
Long run unit | HP9335C SA 10-60K XL | ||||||
Nominal Ratings(kVA) | 10 | 20 | 30 | 40 | 50 | 60 | |
Input | |||||||
Nominal input voltage(V) | 200/208/220 | ||||||
Input voltage range(V) | 166-261Vac (line-line), full load; | ||||||
Nominal input frequency(Hz) | 50/60 | ||||||
Input frequency range(Hz) | 40-70 | ||||||
Bypass voltage tolerance(%) | Upper limit: +10%, +15%, or +20% default: +15%; Lower limit: -10%, -20%, -30% or -40% default: -20% | ||||||
Bypass frequency tolerance(%) | +/- 10% or +/- 20%, default: +/-10% | ||||||
Input power factor | >0.99 | ||||||
Current THD at full linear load(THDi%) | <3% | ||||||
Battery | |||||||
Battery voltage | Standard unit | 30pcs 12V 7AH | 2×30pcs12V7AH | - | - | - | |
Long run unit | ±192V~±264Vdc; battery quantity 32-44 pcs (optional) | ||||||
Temperature compensation (mV/ºC/Cell) | -3.0 (selectable from 0 to -5.0 around 25°C or 30°C, or inhibit) | ||||||
Battery charger current(A) | 0~20( adjustable) | ||||||
Output | |||||||
Nominal output voltage(V) | 200/208/220 | ||||||
Nominal output frequency(Hz) | 50/60 | ||||||
Output power factor | 1 | 1 | 0.9 | 1 | 1 | 0.9 | |
THDv with 100% linear load(%) | <1% | ||||||
Inverter overload capacity | 110% for 60 min; 125% 10min; 150% for 1 min | ||||||
Efficiency | |||||||
Online mode efficiency | Up to 96.5% | ||||||
ECO-Mode efficiency | Up to 99.1% | ||||||
Parallel | Parallel up to 6 units | ||||||
Dimensions and weight | |||||||
Dimensions(W×D×H)mm | Standard unit | 300×700×1105 | 300×700×1105 | 300×810×1260 | - | - | - |
Long run unit (XL) | 300×700×800 | 360×800×980 | |||||
Weight(kg) | Standard unit | 146 | 146 | 194 | - | - | - |
Long run unit (XL) | 74 | 75 | 75 | 115 | 116 | 118 | |
General | |||||||
Noise at 1m dB(A) | <55dB (1 meter away) | ||||||
Altitude | ≤1500; derate power by 1% per 100m between 1500m and 300m | ||||||
Ventilation | Front to back standard | ||||||
Protection level | IP20 | ||||||
EMC standars | EN62040-2 / IEC62040-2 | ||||||
Method of specifying the performance and test | EN62040-3 / IEC62040-3 |