ECO 208V 15-300kVA Modular UPS
Introduction:
ECO 208V 15-300kVA modular UPS is developed for America market. It uses on-line double conversion and advanced DSP digital control technology, resulting in the highest levels of reliability. The UPS is three phase in, three phase out, with each module 15/25/30kVA. It's available from 15kVA to 300kVA unit capacity, and parallel 4 units to 1200kVA.
Scenarios:
Medium data centers, server rooms
Telecom, IT equipment, group enterprises,
and other mission-critical applications
Features:
1.Centralized bypass, centralized control, modular design
2.Online double conversion and three level technology
3.DSP digital control technology
4.Wide input voltage range
5.Output power factor 1
6.High power density with size 440mm*620mm*2U
7.Cold start (battery start up)
8.ECO mode operation
9.Intelligent battery management
10.N+X redundancy
11.Communications: RS485/Relay card/USB/SNMP option
12.Optional emergency power off (EPO) function
13.Compatible with lithium battery applications
Benefits:
1.Modular design, improves maintainability and reliability
2.ECO mode operation for energy saving
3.Cold start for easy operation
4.Communications for network management and remote monitoring
5.N+X redundancy, expanding as required, saves initial investment
Mode | |||||
Capacity | ips Cabine | 15~150kVA | 25~250kVA | 30~300kVA | |
ips Module | 15kVA | 25kVA | 30kVA | ||
Module Quantity | 1~10 | ||||
Input | Phase | 3 Phase 4 Wires and Ground | |||
Rated Voltage | 208Vac | ||||
Frequency Range | 40Hz-70Hz | ||||
Power Factor | 20.99 | ||||
Current THDi | s3%(100%linear load | ||||
Power Walking In | Yes | ||||
Bypass back irrigation | Bypass back irrigation | ||||
Generator access | Yes | ||||
Output | Phase | 3 Phase 4 Wires and Ground | |||
Rated Voltage | 208Vac | ||||
Power Factor | 1 | ||||
Voltage Regulator | +1% | ||||
Frequency | Utility Mode | ±1%±2%±4%±5%,±10%of the rated frequency(optional | |||
Battery Mode | (60±0.1%)Hz | ||||
Crest Factor | 3:1 | ||||
THD | s2%with linear load,s5%with non linear load | ||||
Efficiency | 96% | ||||
Overload | ≤110%,to bypass after 60min;s 125%,to bypass after 10min;s 150%,to bypass after 1min |
||||
Battery | Voltage | ±120VDC | |||
Charging Current | UPS Cabinet | 30A Max | 50A Max | 100A Max. | |
UPS Module | 10A Max | ||||
Transfer Time | Utiity to Battery:0ms;Utility to bypass:Oms | ||||
Protection | Alarm | overload,utility abnormal,UPS fault,battery low,etc | |||
Protection | short circuit,overload,over temperature,battery low,fan fault alarm | ||||
Communication Interface | RS232,RS485,Intelligent slot x 2,Dry Contact,SNMP | ||||
Environment | Operating Temperature | 0°ºC~40ºC | |||
Storage Temperature | -25ºC-55ºC | ||||
Humidity | 0~95%non condensing | ||||
Altitude | <1500m | ||||
Other | Unit Dimensions(D*W*H |
Cabinet(mm) | 850×600×1350 850×600×2000 |
850×600×2000 120×600×2000 |
850×600×2000 120×600×2000 |
Module(mm | 620×440×86 | 620×440×131 | 620×440×131 | ||
Weight (Kg | Cabine | 170/275 | 272/380 | 272/380 | |
Module | 21 | 33 | 33 | ||
Standards | EN62040-1,EN62040-2 |