• Power Supply New Design Frame Mounted Modular UPS Power 20kVA 40kVA 60kVA 80kVA 100kVA 120kVA for Network and IDC Room
  • Power Supply New Design Frame Mounted Modular UPS Power 20kVA 40kVA 60kVA 80kVA 100kVA 120kVA for Network and IDC Room
  • Power Supply New Design Frame Mounted Modular UPS Power 20kVA 40kVA 60kVA 80kVA 100kVA 120kVA for Network and IDC Room
  • Power Supply New Design Frame Mounted Modular UPS Power 20kVA 40kVA 60kVA 80kVA 100kVA 120kVA for Network and IDC Room
  • Power Supply New Design Frame Mounted Modular UPS Power 20kVA 40kVA 60kVA 80kVA 100kVA 120kVA for Network and IDC Room
  • Power Supply New Design Frame Mounted Modular UPS Power 20kVA 40kVA 60kVA 80kVA 100kVA 120kVA for Network and IDC Room

Power Supply New Design Frame Mounted Modular UPS Power 20kVA 40kVA 60kVA 80kVA 100kVA 120kVA for Network and IDC Room

Phase: Three Phase
Type: On-line
Protection: Lightning
Application: Communication
Classification: Lighting/Power
Standby Time: Long-acting Machine
Customization:
Gold Member Since 2024

Suppliers with verified business licenses

Guangdong, China
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
to see all verified strength labels (20)
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
Overview

Basic Info.

Model NO.
Frame Mounted Modular UPS 20kva-120kva
Standby UPS
Sine Wave Output UPS
Output Capacity
Medium Type
Equipment Mode
Decentralized
Brand
OEM
Lead Time
to Be Negotiated
Power Factor
1.0
Warranty
1 Year
Wave Form
Pure Sine Wave
Transport Package
Carton
Specification
4.6 kg
Trademark
OEM
Origin
Shenzhen China
HS Code
8504402000

Product Description

Product Description


 

Introduction:

FM33 20-180kVA uses frame design, suitable for standard 19 inches network cabinet. It adopts online double conversion technology, which can completely eliminate all kinds of grid problems and provide customers with stable and pure sinusoidal power supply protection. 

 

Scenarios:

Standard 19 inches network cabinet of computer room, IDC room, integrated comprehensive cabinet, etc.

 

Features:

1.Frame mounted design

2.Wide input voltage range

3.Online double conversion and three level technology

4.DSP digital control technology

5.Output power factor 0.9

6.N+X redundancy

7.Communications: RS485/Relay card/USB/SNMP option

8.The number of battery cells is 30-50 adjustable

 

Benefits:

1.Wide input voltage range adapt to harsh power grid

2.DSP technology greatly improve the system reliability

3.4.3-inch color touch screen, graphic display, easy to operate

4.Intelligent battery management extend battery life

 

Detailed Photos

Power Supply New Design Frame Mounted Modular UPS Power 20kVA 40kVA 60kVA 80kVA 100kVA 120kVA for Network and IDC RoomPower Supply New Design Frame Mounted Modular UPS Power 20kVA 40kVA 60kVA 80kVA 100kVA 120kVA for Network and IDC RoomPower Supply New Design Frame Mounted Modular UPS Power 20kVA 40kVA 60kVA 80kVA 100kVA 120kVA for Network and IDC RoomPower Supply New Design Frame Mounted Modular UPS Power 20kVA 40kVA 60kVA 80kVA 100kVA 120kVA for Network and IDC Room
Power Supply New Design Frame Mounted Modular UPS Power 20kVA 40kVA 60kVA 80kVA 100kVA 120kVA for Network and IDC RoomPower Supply New Design Frame Mounted Modular UPS Power 20kVA 40kVA 60kVA 80kVA 100kVA 120kVA for Network and IDC Room
Power Supply New Design Frame Mounted Modular UPS Power 20kVA 40kVA 60kVA 80kVA 100kVA 120kVA for Network and IDC Room
Power Supply New Design Frame Mounted Modular UPS Power 20kVA 40kVA 60kVA 80kVA 100kVA 120kVA for Network and IDC RoomPower Supply New Design Frame Mounted Modular UPS Power 20kVA 40kVA 60kVA 80kVA 100kVA 120kVA for Network and IDC RoomPower Supply New Design Frame Mounted Modular UPS Power 20kVA 40kVA 60kVA 80kVA 100kVA 120kVA for Network and IDC Room

Product Parameters
 
Model      
Capacity Frame  20~60kVA 20~120kVA 20~180kVA
 Module 20kVA/25kVA/30kVA
Max. Module Number 2 4 6
Input  Phase 3 Phase 4 Wires and Ground
Rated Voltage 380/400/415Vac 
Voltage Range 138~485Vac
Frequency Range 40Hz-70Hz
Power Factor ≥0.99
Current THDi ≤3%(100% linear load) 
Bypass Voltage Range  Max.voltage: 220V:+25 %( optional +10%, +15%, +20%); 230V:+20 %( optional +10%, +15%);   240V:+15 %( optional +10%);Min. voltage: -45% (optional -20%,-30%)
Frequency protection range: ±10%
Generator access Yes
Output Phase  3 Phase 4 Wires and Ground
Rated Voltage 380/400/415Vac 
Power Factor 0.9 or 1
Voltage Regulation ±1%
Frequency Utility Mode ±1%,±2%,±4%,±5%,±10% of the rated frequency(optional)
Battery Mode (50/60±0.1%)Hz
Crest Factor 3:1
THD ≤2% with linear load, ≤5% with non linear load 
Efficiency 96%
Overload ≤ 110%: to bypass after 60 min, ≤ 125%: to bypass after 10 min, ≤ 150%: to bypass after 1 min
Battery Voltage ±180V/192V/±204V/±216V/±228V/±240/±252/±264/±276/±288/±300Vdc(30/32/34/36/38/40/42/44/46/48/50pcs optional)
Charging Current UPS Cabinet 20A Max. 40A Max. 60A Max. 
UPS Module 10A Max.
Transfer Time Utility to Battery : 0ms; Utility to bypass: 0ms
Protection Alarm overload, utility abnormal, UPS fault, battery low, etc
Protection short circuit, overload, over temperature, battery low, fan fault alarm
Communication Interface RS232, RS485, Intelligent slot x 2, Dry Contact,SNMP
Environment Operating Temperature 0ºC~40ºC
Storage Temperature -25ºC~55ºC
Humidity 0~95% non condensing
Altitude < 1500m
Other Unit Dimensions(D*W*H) Frame 780x485x487 780x485x663 810x485x755
Module 620x440x86mm
Weight (Kg) Frame 45 60 80
Module 20.8/21/21
Standards EN62040-1, EN62040-2

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2024

Suppliers with verified business licenses

Manufacturer/Factory
Number of Employees
6
Year of Establishment
2023-11-22