Customization: | Available |
---|---|
Phase: | Single Phase |
Type: | On-line |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Item | Model | |||
Capacity | VA / Watts | 1KVA / 0.8KW or 0.9KW | 2KVA / 1.6KW or 1.8KW | 3KVA / 2.4KW or 2.7KW |
input | Normal voltage | 220VAC or 110VAC | ||
Turn on Voltage range | (115+-5~300+-5)VAC or ( 60+-5-138+-5)VAC | |||
Frequency range | 40~60Hz(adjustable) | 40~60Hz(adjustable) | 40~60Hz(adjustable) | |
Input power factor | >0.99(220VAC,full R load) | |||
Generator | Support generator input(Generator rating≥2*UPS rating ) | |||
line low loss/comeback | 220VAC:(110±5)VAC/(195±5)VAC when Load≤55%, 110VAC:(60±3)VAC/(65±3)VAC when load≤40% | |||
220VAC:(130±5)VAC/(195±5)VAC when56%< Load≤65%, 110VAC:(60±3)VAC/(75±3)VAC when40%< load≤50% | ||||
220VAC:(150±5)VAC/(195±5)VAC when66%< Load≤70%, 110VAC:(70±3)VAC/(75±3)VAC when50%< load≤60% | ||||
220VAC:(160±5)VAC/(195±5)VAC when71%< Load≤90%, 110VAC:(70±3)VAC/(85±3)VAC when60%< load≤70% | ||||
220VAC:(185±5)VAC/(195±5)VAC when Load>90%, 110VAC:(90±3)VAC/(95±3)VAC when load>70% | ||||
Output | Voltage range | 200VAC/208VAC/220VAC/230VAC/240VAC/110VAC/120VAC, need confirm before order | ||
Frequency range | 50Hz or 60HZ+-0.2Hz(Battery mode) | |||
Wave form | Pure Sine Wave | |||
Transfer time | 0 ms, Between Line mode and Bat mode | |||
Transfer time: 4ms (typical 2.5ms), line Mode and bypass mode | ||||
Distortion | ≤4%,Full linear load | ≤4%,Full linear load | ≤4%,Full linear load | |
Degree of distortion | ≤7%,Full nonlinear load | ≤7%,Full nonlinear load | ≤7%,Full nonlinear load | |
Overload capacity | <105% warning only, <125% 30s ; <150% 20s,>150%, 300MS to bypass | |||
Load peak ratio | 3:1(max) | |||
Standard Modes XG1-3K | Battery Type | Maintenance free valve regulated lead acid (VRLA) battery | ||
Battery voltage | 24VDC or 36VDC | 48VDC or 72VDC | 72VDC or 96VDC | |
Internal Battery | 2*7AH(9AH) or 3*7AH | 4*7AH(9AH) or 6*7AH or 8*7AH | 6*7AH(9AH) or 8*7AH | |
Recharge time | 5 hours to 90%capacity | |||
Charge Current | 1A | 1A | 1A | |
Long backup ModeXG1-3KL | Battery bank | 36VDC, External | 72VDC,External | 96VDC,External |
Charge Current | 5Amp,Max 7Amp | 5Amp,Max 7Amp | 5Amp,Max 7Amp | |
Display | LED Mode | Load level / Battery level / Battery mode / Line mode / Inverter , Bypass ,Over load , Fault | ||
LCD Mode | input output HZ/VAC, Bat %/VDC, Load % and VA/Watts,Temp.LCD For input output HZ/VAC, Bat %/VDC, Load % and VA/Watts,Temp. LED for line,bat, Inverter, Bypss | |||
Audible Alarm | Battery Mode | Beeping every 4 seconds (re-settable) and every second when battery low | ||
Overload | Beeping twice every second | |||
Fault | Beeping Continuously | |||
Bettery low/charger fault | Beeping every 1 second | |||
Bypass mode | Beeping every 2 min | |||
L/N inverse | Beeping every 2 min | |||
Communications | RS-232/USB Interface | With monitoring software | ||
Working Environment | Surge protection | RJ-45 I/O port available for network or Fax/Modem | ||
Working temperature | - 20ºC~40ºC | |||
Humidity | 0-95% non-condensing | |||
Product size | WxDxH (mm) | 350*145*230(H) | 430*190*328(H) | 430*190*328(H) |
PCS/CTN | 2 | 1 | 1 | |
CTN size | WxDxH (mm) | 495*470*340(H) | 570*305*450 (H) | 570*305*450 (H) |
N/W, CTN XG1-3K | Kg | 19/23 (base on 7AH) | 19/23/28 (base on 7AH) | 24/28 (base on 7AH) |
N/W, CTN XG1-3KL | 12 | 12 | 12 | |
G/W, CTN XG1-3K | Kg | 21/25 | 21/25/30 | 25/30 |
G/W, CTN XG1-3KL | 15 | 14 | 14 | |
REMARK | XG*K --- Standard Type Internal battery, XG*KL Long Time Type,External battery |