Customization: | Available |
---|---|
Phase: | Single Phase |
Type: | Line Interactive |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Modular design
All units adopt modular design, including power module, bypass module, monitoring module, can be easily integrated in MDC or customized cabinet.
Power module, Bypass module, Monitoring module, ECU control module, all these modules are hot-swappable.
High reliability
Wide input voltage range, line voltage range is 138-485V, UPS will derate to 40% when the input voltage is below 305V.
UPS adopts multiple digital bus and redundancy parallel control systems, making sure the whole system keep online if any single circuit fail.
The UPS will keep on single or parallel working if any module fail.
Thickened conformal coating, applicable for harsh environments such as high heat, high humidity, dust, salt spray.
Green and power-saving
High input power factor, it is up to 0.99.
3-level topology design, efficiency is up to 95.8% .
THDi<3% (100% linear load) .
The UPS will work in sleeping mode when the load is very small.
LBS function
LBS function can realize 2 independent UPS systems work in synchronization, and it enhances the reliability of the system.
Parallel redundancy function
Support parallel expanded operation: maximum is 6 units.
Support sharing batteries for the UPS in parallel.
Flexible battery configuration
The batteries number of each group can be selected from 30 pieces to 50 pieces.
Large charging current can meet the requirement of long-time backup.
Strong load capacity
Output power factor is 1.0, UPS can supply power to 100% unbalanced load.
High adaptability for load, it can connect full inductive load or capacitive load.
Intelligent management
With 7 inches (standard) and 10 inches (optional) colorful touch LCD screen.
Support recording and exporting history logs and fault logs.
Support SNMP, RS232, RS485, BMS, Dry contact interface.
Support upgrade of CAN of power module inside of cabinet.
EPO & REPO function.
Compatible with generator
Power Walk In function, it can reduce the start current impact to system, and it can reduce the capacity of the generator.
Module Model | HPM3300E-RM-10| HPM3300E-RM-15 | HPM3300E-RM-20| HPM3300E-RM-25 | HPM3300E-RM-30 | ||||
Cabinet Model | HPM3300E-100 | HPM3300E-150 | HPM3300E-200 | HPM3300E-250 | HPM3300E-300 | ||
Cabmet capacity (VA) | 100k | 150k | 200k | 250k | 300k | ||
Module capacty (VA) | 10k | 15k | 20k | 25k | 30k | ||
Max,number | 10 | ||||||
INPUT Nommal voltage | 38V400V415Vac,(3Ph+N+PE) | ||||||
Operating woltage range | 138-305Vac for 40% load; 305-485Vac for 100% load | ||||||
Operating frequency range | 40Hz-70Hz | ||||||
Power factor | 0.99 | ||||||
Harmoric distorion (THD) | ≤3%(100% linear bad) | ||||||
Bypass voltage range | Max,votage220V:+25%(optional+10%,+15%,+20%); 230V:+20%(optional+10%,+15%);240V:+15%(optional+10%) Min voltage:-45%(optional-10%,-15%,-20%,-30%) |
||||||
Bvpass fequency range | Frequency protedion range:±10% | ||||||
Power Walk In | Support | ||||||
Generator inp | ut | Support | |||||
OUTPUT | |||||||
Rated voltage | 380/400/415Vac,(3Ph+N+PE) | ||||||
Power factor | 1.0 | ||||||
Voltage reg.lation | ±1% | ||||||
Output Line mode | Synchronize with input,when the input frequency>±10%(±1%/±2%/±3%/±4%/±5%optional),output 50/60(±0.1Hz) | ||||||
fnequency Bat,mode | (50/60±0.1%)Hz | ||||||
Crest factor | 3:1 | ||||||
Harmonic distortion(THDv) | ≤1%with linear load;=3% with nonlnear load | ||||||
Effciency BATTERY |
up to 95.8% | ||||||
BATTERY | |||||||
Battery voltage | optional Votage:±180/192/204/216/228/240/252/264/276/288/300Vdc(30/32/34/36/38/40/42/44/46/48/50pcs optional) 360Vdc-600Vdc(30-50pcs,36pcs default,36-50 pcs no power derating;32-34 pcs ouput power factor 0.9; 30 pcs ouput power factor 0.8 |
||||||
Power modue charge Current | 18A(Max) | ||||||
System Features | |||||||
Transfer time | Utility to Battery: 0ms; Utility to Bypass: 0ms | ||||||
Line mode | ≤110%,60min; <125%,10min; ≤150%, 1 min; to bypass,>150% Shut down Immediately | ||||||
Overload Bypass mode Overheat |
1359%overoad for long term;>1000%overoad for 100 ms Line Mode:Switch to Bypass;Backup Mode:Shut down UPS immediately |
||||||
Low battery voltage | Alarm and Switch off | ||||||
SeH-diagnastics | Upon Power On and Software Control | ||||||
Backfeed protection | Support | ||||||
EPO (optional) | Shut down UPS immediately (tum to bypass optional) | ||||||
Battery Noise sppression |
Advanced Battery Management Compfie with EN62040-3 |
||||||
Audible &vsual alams | Line Failure,Battery Low,Overload,System Fault | ||||||
Status LED &LCD drspay | Lne Mode,Bypass Mode,Battery Low,Battery Fault,Overload system fault | ||||||
Reading on the LCD dsplay Commurication interface |
nput,Output,Battery,Command,Setting,Maintenance RS232,RS485,Parallel,LBS,BMS,Dry contact port, Relay card(optional),SNMP card(optional),Battery temperature sensor(optional) |
||||||
ENVIRONMENTAL | |||||||
Operatng Storage |
temperature temperature |
0ºC-40ºC | |||||
-25ºC-55ºC | |||||||
Hunidity range | 0-95%(non condensing) | ||||||
Alhitude | <1500m,derating required when >1500m | ||||||
<680B | |||||||
Ncise lewel PHYSICAL |
|||||||
Dimension W×D×H(mm) |
UPScatinet (S/F) Povermode |
600×850×2000 | |||||
440×620×86(2U | |||||||
Netweight (kg) | UPS cabnet (S/F) |
210-300 |