offline ups 3phase input 3phase out 208VAC Online IGBT UPS 10-60KVA with ups backup power supply
Key Features
Double IGBT technical,input PFC>0.99,Thdi<3%;
Efficiency up to 96.5% with three-level technology;
Big charger power reach up to 15% of total power;
Intelligent LCD screen support 12 languages,such as English,Russian.Spanish,French,Korean,Italy,Turkish ;
The internal air channel is designed in such a way that internal hot air drives directly towards the heat sink,
without distressing the PCBs and other internal sensitive circuits.
offline ups 3phase input 3phase out 208VAC Online IGBT UPS 10-60KVA with ups backup power supply
Key Features
Double IGBT technical,input PFC>0.99,Thdi<3%;
Efficiency up to 96.5% with three-level technology;
Big charger power reach up to 15% of total power;
Intelligent LCD screen support 12 languages,such as English,Russian.Spanish,French,Korean,Italy,Turkish ;
The internal air channel is designed in such a way that internal hot air drives directly towards the heat sink,
without distressing the PCBs and other internal sensitive circuits.
HX9335C II 10-120K 3ph Input/3ph Output 380/400/415VAC
Model | Standard unit | HX9335C 10-40KT | - | |||||||
Long run unit | HX9335C 10-120K XL | |||||||||
Nominal Ratings(kVA) | 10 | 20 | 30 | 40 | 50 | 60 | 80 | 100 | 120 | |
Input | ||||||||||
Nominal input voltage(V) | 380/400/415 | |||||||||
Input voltage range(V) | 228-478 | |||||||||
Nominal input frequency(Hz) | 50/60 | |||||||||
Input frequency range(Hz) | 40-70 | |||||||||
Bypass voltage tolerance(%) |
Upper limit: +10%, +15%, or +20% default:+15%; Lower limit: -10%, -20%, -30% or -40% default: -20% |
|||||||||
Bypass frequency tolerance(%) | +/- 10% or +/- 20%, default: +/-10% | |||||||||
Input power factor | >0.99 | |||||||||
Current THD at full linear load(THDi%) | <3% | |||||||||
Battery | ||||||||||
Battery voltage | Standard unit | 30pcs 12V 7AH | 30pcs 12V 7AH | 60pcs 12V 7AH | 64pcs 12V 9AH | - | ||||
Long run unit | ±192V~±264Vdc; battery quantity 32-44 pcs (optional) | |||||||||
Temperature compensation (mV/ºC/Cell) | -3.0 (selectable from 0 to -5.0 around 25°C or 30°C, or inhibit) | |||||||||
Battery charger current(A) | 0~20( adjustable) | 0~40( adjustable) | ||||||||
Output | ||||||||||
Nominal output voltage(V) | 380/400/415 | |||||||||
Nominal output frequency(Hz) | 50/60 | |||||||||
Output power factor | 1 | 1 | 1 | 1 | 1 | 0.9 | 1 | 1 | 0.9 | |
THDv with 100% linear load(%) | <1% | |||||||||
Inverter overload capacity | 110% for 60 min; 125% 10min; 150% for 1 min | |||||||||
Efficiency | ||||||||||
Online mode efficiency | Up to 96.5% | |||||||||
ECO-Mode efficiency | Up to 99.1% | |||||||||
Parallel | Parallel up to 6 units | |||||||||
Dimensions and weight | ||||||||||
Dimensions(W×D×H)mm | Standard unit | 300×700×1105 | 300×810×1260 | - | ||||||
Long run unit | 300×700×800 | 360×800×980 | ||||||||
Weight(kg) | Standard unit | 146 | 146 | 194 | 198 | - | ||||
Long run unit | 74 | 74 | 74 | 75 | 75 | 75 | 115 | 116 | 118 | |
General | ||||||||||
Noise at 1m dB(A) | <55dB (1 meter away) | <60dB (1 meter away) | ||||||||
Altitude | ≤1500; derate power by 1% per 100m between 1500m and 300m | |||||||||
Ventilation | Front to back standard | |||||||||
Protection level | IP20 | |||||||||
General and safety | EN62040-1/IEC62040-1 | |||||||||
EMC standars | EN62040-2 / IEC62040-2 | |||||||||
Method of specifying the performance and test | EN62040-3 / IEC62040-3 |
HX9335C II SA 10-60KT 3ph Input/3ph Output 200/208/220VAC
Model | Standard unit | HX9335C SA 10-30KT | - | ||||
Long run unit | HX9335C SA 10-60K XL | ||||||
Nominal Ratings(kVA) | 10 | 20 | 30 | 40 | 50 | 60 | |
Input | |||||||
Nominal input voltage(V) | 200/208/220 | ||||||
Input voltage range(V) | 166-261Vac (line-line), full load; | ||||||
Nominal input frequency(Hz) | 50/60 | ||||||
Input frequency range(Hz) | 40-70 | ||||||
Bypass voltage tolerance(%) | Upper limit: +10%, +15%, or +20% default: +15%; Lower limit: -10%, -20%, -30% or -40% default: -20% | ||||||
Bypass frequency tolerance(%) | +/- 10% or +/- 20%, default: +/-10% | ||||||
Input power factor | >0.99 | ||||||
Current THD at full linear load(THDi%) | <3% | ||||||
Battery | |||||||
Battery voltage | Standard unit | 30pcs 12V 7AH | 2×30pcs12V7AH | - | - | - | |
Long run unit | ±192V~±264Vdc; battery quantity 32-44 pcs (optional) | ||||||
Temperature compensation (mV/ºC/Cell) | -3.0 (selectable from 0 to -5.0 around 25°C or 30°C, or inhibit) | ||||||
Battery charger current(A) | 0~20( adjustable) | ||||||
Output | |||||||
Nominal output voltage(V) | 200/208/220 | ||||||
Nominal output frequency(Hz) | 50/60 | ||||||
Output power factor | 1 | 1 | 0.9 | 1 | 1 | 0.9 | |
THDv with 100% linear load(%) | <1% | ||||||
Inverter overload capacity | 110% for 60 min; 125% 10min; 150% for 1 min | ||||||
Efficiency | |||||||
Online mode efficiency | Up to 96.5% | ||||||
ECO-Mode efficiency | Up to 99.1% | ||||||
Parallel | Parallel up to 6 units | ||||||
Dimensions and weight | |||||||
Dimensions(W×D×H)mm | Standard unit | 300×700×1105 | 300×700×1105 | 300×810×1260 | - | - | - |
Long run unit (XL) | 300×700×800 | 360×800×980 | |||||
Weight(kg) | Standard unit | 146 | 146 | 194 | - | - | - |
Long run unit (XL) | 74 | 75 | 75 | 115 | 116 | 118 | |
General | |||||||
Noise at 1m dB(A) | <55dB (1 meter away) | ||||||
Altitude | ≤1500; derate power by 1% per 100m between 1500m and 300m | ||||||
Ventilation | Front to back standard | ||||||
Protection level | IP20 | ||||||
EMC standars | EN62040-2 / IEC62040-2 | ||||||
Method of specifying the performance and test | EN62040-3 / IEC62040-3 |